{"id":6535,"date":"2026-06-08T14:29:57","date_gmt":"2026-06-08T14:29:57","guid":{"rendered":"https:\/\/novanta.com\/precision-medicine\/?post_type=novanta_tech_paper&#038;p=6535"},"modified":"2026-06-17T15:25:53","modified_gmt":"2026-06-17T15:25:53","slug":"precision-wavelength-calibration-for-display-spectroradiometers-a-reproducibility-study","status":"publish","type":"novanta_tech_paper","link":"https:\/\/novanta.com\/precision-medicine\/technical-paper\/precision-wavelength-calibration-for-display-spectroradiometers-a-reproducibility-study\/","title":{"rendered":"Precision Wavelength Calibration for Display Spectroradiometers: A Reproducibility Study"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Wide gamut laser displays, microLED, and OLED technologies demand high spectral accuracy and low measurement uncertainty, making robust calibration essential for reliable metrology. This study evaluates the reproducibility of a four-line laser diode wavelength calibration method for spectroradiometers using Gage Repeatability and Reproducibility (Gage R&#038;R) analysis. Measurements were performed on three qualified spectroradiometers using a known spectral line from a mercury (Hg) lamp. The results show negligible operator influence and low repeatability error, with an expanded uncertainty below \u00b1 0.1 nm. The method demonstrates strong reproducibility and sensitivity to systematic errors, making it suitable for production environments and instrument diagnostics.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Wide gamut laser displays, microLED, and OLED technologies demand high spectral accuracy and low measurement uncertainty, making robust calibration essential for reliable metrology. This study evaluates the reproducibility of a four-line laser diode wavelength calibration method for spectroradiometers using Gage Repeatability and Reproducibility (Gage R&#038;R) analysis. Measurements were performed on three qualified spectroradiometers using a [&hellip;]<\/p>\n","protected":false},"author":365,"featured_media":6536,"template":"","meta":{"_acf_changed":true,"card_thumbnail_id":0,"show_table_of_content":true},"class_list":["post-6535","novanta_tech_paper","type-novanta_tech_paper","status-publish","has-post-thumbnail","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.0 (Yoast SEO v27.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Precision Wavelength Calibration for Display Spectroradiometers: A Reproducibility Study - Precision Medicine<\/title>\n<meta name=\"description\" content=\"Evaluate a reproducible wavelength calibration method for spectroradiometers, achieving \u00b10.08 nm uncertainty for accurate display metrology and QC workflows. [Precision...lity Study | Word]\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/novanta.com\/precision-medicine\/technical-paper\/precision-wavelength-calibration-for-display-spectroradiometers-a-reproducibility-study\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Precision Wavelength Calibration for Display Spectroradiometers: A Reproducibility Study\" \/>\n<meta property=\"og:description\" content=\"Evaluate a reproducible wavelength calibration method for spectroradiometers, achieving \u00b10.08 nm uncertainty for accurate display metrology and QC workflows. [Precision...lity Study | Word]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/novanta.com\/precision-medicine\/technical-paper\/precision-wavelength-calibration-for-display-spectroradiometers-a-reproducibility-study\/\" \/>\n<meta property=\"og:site_name\" content=\"Precision Medicine\" \/>\n<meta property=\"article:modified_time\" content=\"2026-06-17T15:25:53+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/novanta.com\/precision-medicine\/wp-content\/uploads\/sites\/36\/2026\/06\/Precision-Wavelength-White-Paper-Hero.png?resize=1200,640\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"640\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/novanta.com\\\/precision-medicine\\\/technical-paper\\\/precision-wavelength-calibration-for-display-spectroradiometers-a-reproducibility-study\\\/\",\"url\":\"https:\\\/\\\/novanta.com\\\/precision-medicine\\\/technical-paper\\\/precision-wavelength-calibration-for-display-spectroradiometers-a-reproducibility-study\\\/\",\"name\":\"Precision Wavelength Calibration for Display Spectroradiometers: A Reproducibility Study - Precision Medicine\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/novanta.com\\\/precision-medicine\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/novanta.com\\\/precision-medicine\\\/technical-paper\\\/precision-wavelength-calibration-for-display-spectroradiometers-a-reproducibility-study\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/novanta.com\\\/precision-medicine\\\/technical-paper\\\/precision-wavelength-calibration-for-display-spectroradiometers-a-reproducibility-study\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/novanta.com\\\/precision-medicine\\\/wp-content\\\/uploads\\\/sites\\\/36\\\/2026\\\/06\\\/Precision-Wavelength-White-Paper-Hero.png?quality=85&strip=all\",\"datePublished\":\"2026-06-08T14:29:57+00:00\",\"dateModified\":\"2026-06-17T15:25:53+00:00\",\"description\":\"Evaluate a reproducible wavelength calibration method for spectroradiometers, achieving \u00b10.08 nm uncertainty for accurate display metrology and QC workflows. [Precision...lity Study | Word]\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/novanta.com\\\/precision-medicine\\\/technical-paper\\\/precision-wavelength-calibration-for-display-spectroradiometers-a-reproducibility-study\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/novanta.com\\\/precision-medicine\\\/technical-paper\\\/precision-wavelength-calibration-for-display-spectroradiometers-a-reproducibility-study\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/novanta.com\\\/precision-medicine\\\/technical-paper\\\/precision-wavelength-calibration-for-display-spectroradiometers-a-reproducibility-study\\\/#primaryimage\",\"url\":\"https:\\\/\\\/novanta.com\\\/precision-medicine\\\/wp-content\\\/uploads\\\/sites\\\/36\\\/2026\\\/06\\\/Precision-Wavelength-White-Paper-Hero.png?quality=85&strip=all\",\"contentUrl\":\"https:\\\/\\\/novanta.com\\\/precision-medicine\\\/wp-content\\\/uploads\\\/sites\\\/36\\\/2026\\\/06\\\/Precision-Wavelength-White-Paper-Hero.png?quality=85&strip=all\",\"width\":1920,\"height\":640},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/novanta.com\\\/precision-medicine\\\/technical-paper\\\/precision-wavelength-calibration-for-display-spectroradiometers-a-reproducibility-study\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/novanta.com\\\/precision-medicine\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Precision Wavelength Calibration for Display Spectroradiometers: A Reproducibility Study\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/novanta.com\\\/precision-medicine\\\/#website\",\"url\":\"https:\\\/\\\/novanta.com\\\/precision-medicine\\\/\",\"name\":\"Precision Medicine\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/novanta.com\\\/precision-medicine\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Precision Wavelength Calibration for Display Spectroradiometers: A Reproducibility Study - Precision Medicine","description":"Evaluate a reproducible wavelength calibration method for spectroradiometers, achieving \u00b10.08 nm uncertainty for accurate display metrology and QC workflows. [Precision...lity Study | Word]","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/novanta.com\/precision-medicine\/technical-paper\/precision-wavelength-calibration-for-display-spectroradiometers-a-reproducibility-study\/","og_locale":"en_US","og_type":"article","og_title":"Precision Wavelength Calibration for Display Spectroradiometers: A Reproducibility Study","og_description":"Evaluate a reproducible wavelength calibration method for spectroradiometers, achieving \u00b10.08 nm uncertainty for accurate display metrology and QC workflows. [Precision...lity Study | Word]","og_url":"https:\/\/novanta.com\/precision-medicine\/technical-paper\/precision-wavelength-calibration-for-display-spectroradiometers-a-reproducibility-study\/","og_site_name":"Precision Medicine","article_modified_time":"2026-06-17T15:25:53+00:00","og_image":[{"width":1200,"height":640,"url":"https:\/\/novanta.com\/precision-medicine\/wp-content\/uploads\/sites\/36\/2026\/06\/Precision-Wavelength-White-Paper-Hero.png?resize=1200,640","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/novanta.com\/precision-medicine\/technical-paper\/precision-wavelength-calibration-for-display-spectroradiometers-a-reproducibility-study\/","url":"https:\/\/novanta.com\/precision-medicine\/technical-paper\/precision-wavelength-calibration-for-display-spectroradiometers-a-reproducibility-study\/","name":"Precision Wavelength Calibration for Display Spectroradiometers: A Reproducibility Study - Precision Medicine","isPartOf":{"@id":"https:\/\/novanta.com\/precision-medicine\/#website"},"primaryImageOfPage":{"@id":"https:\/\/novanta.com\/precision-medicine\/technical-paper\/precision-wavelength-calibration-for-display-spectroradiometers-a-reproducibility-study\/#primaryimage"},"image":{"@id":"https:\/\/novanta.com\/precision-medicine\/technical-paper\/precision-wavelength-calibration-for-display-spectroradiometers-a-reproducibility-study\/#primaryimage"},"thumbnailUrl":"https:\/\/novanta.com\/precision-medicine\/wp-content\/uploads\/sites\/36\/2026\/06\/Precision-Wavelength-White-Paper-Hero.png?quality=85&strip=all","datePublished":"2026-06-08T14:29:57+00:00","dateModified":"2026-06-17T15:25:53+00:00","description":"Evaluate a reproducible wavelength calibration method for spectroradiometers, achieving \u00b10.08 nm uncertainty for accurate display metrology and QC workflows. [Precision...lity Study | Word]","breadcrumb":{"@id":"https:\/\/novanta.com\/precision-medicine\/technical-paper\/precision-wavelength-calibration-for-display-spectroradiometers-a-reproducibility-study\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/novanta.com\/precision-medicine\/technical-paper\/precision-wavelength-calibration-for-display-spectroradiometers-a-reproducibility-study\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/novanta.com\/precision-medicine\/technical-paper\/precision-wavelength-calibration-for-display-spectroradiometers-a-reproducibility-study\/#primaryimage","url":"https:\/\/novanta.com\/precision-medicine\/wp-content\/uploads\/sites\/36\/2026\/06\/Precision-Wavelength-White-Paper-Hero.png?quality=85&strip=all","contentUrl":"https:\/\/novanta.com\/precision-medicine\/wp-content\/uploads\/sites\/36\/2026\/06\/Precision-Wavelength-White-Paper-Hero.png?quality=85&strip=all","width":1920,"height":640},{"@type":"BreadcrumbList","@id":"https:\/\/novanta.com\/precision-medicine\/technical-paper\/precision-wavelength-calibration-for-display-spectroradiometers-a-reproducibility-study\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/novanta.com\/precision-medicine\/"},{"@type":"ListItem","position":2,"name":"Precision Wavelength Calibration for Display Spectroradiometers: A Reproducibility Study"}]},{"@type":"WebSite","@id":"https:\/\/novanta.com\/precision-medicine\/#website","url":"https:\/\/novanta.com\/precision-medicine\/","name":"Precision Medicine","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/novanta.com\/precision-medicine\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/novanta.com\/precision-medicine\/wp-json\/wp\/v2\/novanta_tech_paper\/6535","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/novanta.com\/precision-medicine\/wp-json\/wp\/v2\/novanta_tech_paper"}],"about":[{"href":"https:\/\/novanta.com\/precision-medicine\/wp-json\/wp\/v2\/types\/novanta_tech_paper"}],"author":[{"embeddable":true,"href":"https:\/\/novanta.com\/precision-medicine\/wp-json\/wp\/v2\/users\/365"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/novanta.com\/precision-medicine\/wp-json\/wp\/v2\/media\/6536"}],"wp:attachment":[{"href":"https:\/\/novanta.com\/precision-medicine\/wp-json\/wp\/v2\/media?parent=6535"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}