{"id":3266,"date":"2019-05-02T16:15:04","date_gmt":"2019-05-02T16:15:04","guid":{"rendered":"https:\/\/novanta.com\/robotics-automation\/technical-paper\/optical-encoder-grounding-and-shielding-recommendations\/"},"modified":"2026-04-07T06:45:31","modified_gmt":"2026-04-07T06:45:31","slug":"optical-encoder-grounding-and-shielding-recommendations","status":"publish","type":"novanta_tech_paper","link":"https:\/\/novanta.com\/robotics-automation\/technical-paper\/optical-encoder-grounding-and-shielding-recommendations\/","title":{"rendered":"Optical Encoder Grounding and Shielding Recommendations"},"content":{"rendered":"\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-heading\" id=\"introduction\"><strong>Introduction<\/strong><\/h2>\n\n\n\n<p>Proper shielding and grounding are essential to good servo design. Selecting the appropriate cable and devoting effort to the grounding of the encoder in the planning stage will save considerable time and expense in troubleshooting and correcting signal noise problems once the design is complete.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"shielding\"><strong>Shielding<\/strong><\/h2>\n\n\n\n<p>A cable can transfer noise by acting as an antenna or it can pick up noise that is radiated from other equipment. Proper wiring and shielding can mitigate the effects of signal interference by reflecting it from the signal carrying wires and by conducting the interference to ground.<\/p>\n\n\n\n<p>MicroE encoders feature double-shielded cables with twisted differential pairs. The inner shield is connected to circuit ground and the outer shield is connected to both the sensor and the connector housing. When the encoder is connected to ground, either at the sensor or at the connector, a path to ground for electrical noise is provided.<\/p>\n\n\n\n<p><p style=\"text-align: center\"><strong>Cross-section of double-shielded cable<\/strong><\/p><\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-fe9cc265 wp-block-group-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"559\" height=\"337\" src=\"https:\/\/novanta.com\/robotics-automation\/wp-content\/uploads\/sites\/3\/2019\/05\/Cross-section-of-double-shielded-cable-Figure.png\" alt=\"\" class=\"wp-image-3261\" srcset=\"https:\/\/novanta.com\/robotics-automation\/wp-content\/uploads\/sites\/3\/2019\/05\/Cross-section-of-double-shielded-cable-Figure.png?quality=85&amp;strip=all 559w, https:\/\/novanta.com\/robotics-automation\/wp-content\/uploads\/sites\/3\/2019\/05\/Cross-section-of-double-shielded-cable-Figure.png?resize=320%2C193&amp;quality=85&amp;strip=all 320w, https:\/\/novanta.com\/robotics-automation\/wp-content\/uploads\/sites\/3\/2019\/05\/Cross-section-of-double-shielded-cable-Figure.png?resize=400%2C241&amp;quality=85&amp;strip=all 400w\" sizes=\"auto, (max-width: 559px) 100vw, 559px\" \/><figcaption class=\"wp-element-caption\">Figure 1<\/figcaption><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p>The use of twisted pairs takes advantage of differential signaling where one line carries one signal and the other its complement. The signal measured is the difference between the two lines. The differential signal propagated in twisted pairs is more robust to cross talk and will be less susceptible to noise.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-heading\" id=\"grounding\"><strong>Grounding<\/strong><\/h2>\n\n\n\n<p>An effective grounding system will help reduce electromagnetic interference effects from disturbing the encoder signal outputs. A single-point grounding scheme operates better at low frequencies, and a multipoint ground behaves best at high frequencies.In designing a ground system for MicroE sensors, the ground connection would ideally be made at the sensor head; however the bracket that the sensor is mounted to is often attached to moving parts. There is no guarantee that there will be a good ground contact on parts that are moving, so in such cases the ground connection may be best made at the connector.<\/p>\n\n\n\n<p>Figure 2 shows the connections of the inner and outer shields of a MicroE encoder. The first drawing shows the encoder properly grounded, which will offer the best protection against signal noise interference.<\/p>\n\n\n\n<p>Sensor mounted with good electrical contact to well grounded (preferred):<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-fe9cc265 wp-block-group-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"812\" height=\"283\" src=\"https:\/\/novanta.com\/robotics-automation\/wp-content\/uploads\/sites\/3\/2019\/05\/Sensor-mounted-with-good-electrical-contact-to-well-grounded-surface-Figure-2.png\" alt=\"\" class=\"wp-image-3262\" srcset=\"https:\/\/novanta.com\/robotics-automation\/wp-content\/uploads\/sites\/3\/2019\/05\/Sensor-mounted-with-good-electrical-contact-to-well-grounded-surface-Figure-2.png?quality=85&amp;strip=all 812w, https:\/\/novanta.com\/robotics-automation\/wp-content\/uploads\/sites\/3\/2019\/05\/Sensor-mounted-with-good-electrical-contact-to-well-grounded-surface-Figure-2.png?resize=320%2C112&amp;quality=85&amp;strip=all 320w, https:\/\/novanta.com\/robotics-automation\/wp-content\/uploads\/sites\/3\/2019\/05\/Sensor-mounted-with-good-electrical-contact-to-well-grounded-surface-Figure-2.png?resize=400%2C139&amp;quality=85&amp;strip=all 400w\" sizes=\"auto, (max-width: 812px) 100vw, 812px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p>Sensor mounted to poorly grounded or non-conducting surface:<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"812\" height=\"209\" src=\"https:\/\/novanta.com\/robotics-automation\/wp-content\/uploads\/sites\/3\/2019\/05\/Sensor-mounted-to-pooly-grounded-or-non-conducting-surface-Figure-3.png\" alt=\"\" class=\"wp-image-3263\" srcset=\"https:\/\/novanta.com\/robotics-automation\/wp-content\/uploads\/sites\/3\/2019\/05\/Sensor-mounted-to-pooly-grounded-or-non-conducting-surface-Figure-3.png?quality=85&amp;strip=all 812w, https:\/\/novanta.com\/robotics-automation\/wp-content\/uploads\/sites\/3\/2019\/05\/Sensor-mounted-to-pooly-grounded-or-non-conducting-surface-Figure-3.png?resize=320%2C82&amp;quality=85&amp;strip=all 320w, https:\/\/novanta.com\/robotics-automation\/wp-content\/uploads\/sites\/3\/2019\/05\/Sensor-mounted-to-pooly-grounded-or-non-conducting-surface-Figure-3.png?resize=400%2C103&amp;quality=85&amp;strip=all 400w\" sizes=\"auto, (max-width: 812px) 100vw, 812px\" \/><\/figure>\n\n\n\n<p><p style=\"text-align: center\">Figure 2<\/p><\/p>\n\n\n\n<p>For units with 2&#215;5 micro-connectors, the outer shield is terminated at the hex sleeve.<\/p>\n\n\n\n<p>Ground loops can occur when more than one point is used for ground connections causing these points to be at different ground potentials. This difference of potentials can cause noise due to induced AC voltage and electromagnetic interference. Ground loops can occur if the sensor and the connector shell are each grounded separately.<\/p>\n\n\n\n<p>It is unlikely that the sensor mounting bracket and the electrical chassis ground at the receiving end will be at exactly the same electrical potential. For most applications, a single ground connection is recommended.<\/p>\n\n\n\n<p>To stress this point, two different ground symbols have been used in the following illustrations. For systems where the expected noise sources will be relatively low in frequency, grounding at only one point is best \u2013 either the sensor or the connector shell, but not both.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-fe9cc265 wp-block-group-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"631\" height=\"885\" src=\"https:\/\/novanta.com\/robotics-automation\/wp-content\/uploads\/sites\/3\/2019\/05\/Ground-loops-Figure-3.png\" alt=\"\" class=\"wp-image-3264\" srcset=\"https:\/\/novanta.com\/robotics-automation\/wp-content\/uploads\/sites\/3\/2019\/05\/Ground-loops-Figure-3.png?quality=85&amp;strip=all 631w, https:\/\/novanta.com\/robotics-automation\/wp-content\/uploads\/sites\/3\/2019\/05\/Ground-loops-Figure-3.png?resize=320%2C449&amp;quality=85&amp;strip=all 320w, https:\/\/novanta.com\/robotics-automation\/wp-content\/uploads\/sites\/3\/2019\/05\/Ground-loops-Figure-3.png?resize=400%2C561&amp;quality=85&amp;strip=all 400w\" sizes=\"auto, (max-width: 631px) 100vw, 631px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p>In cases where high frequency noise sources exist, such as some medical equipment applications, multiple ground points are desirable. In such cases, using a 0.1\u03bcF capacitor between the connector shell and the ground can be very effective:<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"684\" height=\"380\" src=\"https:\/\/novanta.com\/robotics-automation\/wp-content\/uploads\/sites\/3\/2019\/05\/High-frequency-noise-connector-capacitor-Figure-4.png\" alt=\"\" class=\"wp-image-3265\" srcset=\"https:\/\/novanta.com\/robotics-automation\/wp-content\/uploads\/sites\/3\/2019\/05\/High-frequency-noise-connector-capacitor-Figure-4.png?quality=85&amp;strip=all 684w, https:\/\/novanta.com\/robotics-automation\/wp-content\/uploads\/sites\/3\/2019\/05\/High-frequency-noise-connector-capacitor-Figure-4.png?resize=320%2C178&amp;quality=85&amp;strip=all 320w, https:\/\/novanta.com\/robotics-automation\/wp-content\/uploads\/sites\/3\/2019\/05\/High-frequency-noise-connector-capacitor-Figure-4.png?resize=400%2C222&amp;quality=85&amp;strip=all 400w\" sizes=\"auto, (max-width: 684px) 100vw, 684px\" \/><\/figure>\n\n\n\n<p>In this example, the capacitor will act as an open circuit for low frequency noise (or a DC potential between grounds) and a short circuit for higher frequencies. This technique is highly recommended for applications where high frequency interference is common.<\/p>\n\n\n\n<p><p style=\"padding-left: 40px\"><em>Sources:<\/em>   <em>Henry W. Ott, &#8220;Noise Reduction Techniques In Electronic Systems,&#8221; 1988<\/em><\/p><\/p>\n\n\n\n<p><p style=\"padding-left: 40px\"><em>                  Howard Johnson, &#8220;High-Speed Signal Propagation: Advanced Black Magic,&#8221; 2003<\/em><\/p><\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-fe9cc265 wp-block-group-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Introduction Proper shielding and grounding are essential to good servo design. Selecting the appropriate cable and devoting effort to the grounding of the encoder in the planning stage will save considerable time and expense in troubleshooting and correcting signal noise problems once the design is complete. Shielding A cable can transfer noise by acting as [&hellip;]<\/p>\n","protected":false},"author":100,"featured_media":3260,"template":"","meta":{"_acf_changed":false},"class_list":["post-3266","novanta_tech_paper","type-novanta_tech_paper","status-publish","has-post-thumbnail","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.0 (Yoast SEO v27.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Optical Encoder Grounding &amp; Shielding Recommendations | Celera Motion<\/title>\n<meta name=\"description\" content=\"Learn why proper shielding &amp; grounding are essential to good servo design, &amp; how to save time &amp; money in the installation stage, with installation diagrams.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/novanta.com\/robotics-automation\/technical-paper\/optical-encoder-grounding-and-shielding-recommendations\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Optical Encoder Grounding and Shielding Recommendations\" \/>\n<meta property=\"og:description\" content=\"Learn why proper shielding &amp; grounding are essential to good servo design, &amp; how to save time &amp; money in the installation stage, with installation diagrams.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/novanta.com\/robotics-automation\/technical-paper\/optical-encoder-grounding-and-shielding-recommendations\/\" \/>\n<meta property=\"og:site_name\" content=\"Robotics &amp; Automation\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-07T06:45:31+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/novanta.com\/robotics-automation\/wp-content\/uploads\/sites\/3\/2019\/07\/Grounding-and-Shielding-Recommendations-.jpg?quality=85&strip=all&w=375&h=235&crop=1\" \/>\n\t<meta property=\"og:image:width\" content=\"375\" \/>\n\t<meta property=\"og:image:height\" content=\"235\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/novanta.com\\\/robotics-automation\\\/technical-paper\\\/optical-encoder-grounding-and-shielding-recommendations\\\/\",\"url\":\"https:\\\/\\\/novanta.com\\\/robotics-automation\\\/technical-paper\\\/optical-encoder-grounding-and-shielding-recommendations\\\/\",\"name\":\"Optical Encoder Grounding & Shielding Recommendations | Celera Motion\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/novanta.com\\\/robotics-automation\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/novanta.com\\\/robotics-automation\\\/technical-paper\\\/optical-encoder-grounding-and-shielding-recommendations\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/novanta.com\\\/robotics-automation\\\/technical-paper\\\/optical-encoder-grounding-and-shielding-recommendations\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/novanta.com\\\/robotics-automation\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2019\\\/07\\\/Grounding-and-Shielding-Recommendations-.jpg?quality=85&strip=all\",\"datePublished\":\"2019-05-02T16:15:04+00:00\",\"dateModified\":\"2026-04-07T06:45:31+00:00\",\"description\":\"Learn why proper shielding & grounding are essential to good servo design, & how to save time & money in the installation stage, with installation diagrams.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/novanta.com\\\/robotics-automation\\\/technical-paper\\\/optical-encoder-grounding-and-shielding-recommendations\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/novanta.com\\\/robotics-automation\\\/technical-paper\\\/optical-encoder-grounding-and-shielding-recommendations\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/novanta.com\\\/robotics-automation\\\/technical-paper\\\/optical-encoder-grounding-and-shielding-recommendations\\\/#primaryimage\",\"url\":\"https:\\\/\\\/novanta.com\\\/robotics-automation\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2019\\\/07\\\/Grounding-and-Shielding-Recommendations-.jpg?quality=85&strip=all\",\"contentUrl\":\"https:\\\/\\\/novanta.com\\\/robotics-automation\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2019\\\/07\\\/Grounding-and-Shielding-Recommendations-.jpg?quality=85&strip=all\",\"width\":375,\"height\":235,\"caption\":\"Shielded electrical cables\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/novanta.com\\\/robotics-automation\\\/technical-paper\\\/optical-encoder-grounding-and-shielding-recommendations\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/novanta.com\\\/robotics-automation\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Optical Encoder Grounding and Shielding Recommendations\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/novanta.com\\\/robotics-automation\\\/#website\",\"url\":\"https:\\\/\\\/novanta.com\\\/robotics-automation\\\/\",\"name\":\"Robotics & Automation\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/novanta.com\\\/robotics-automation\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Optical Encoder Grounding & Shielding Recommendations | Celera Motion","description":"Learn why proper shielding & grounding are essential to good servo design, & how to save time & money in the installation stage, with installation diagrams.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/novanta.com\/robotics-automation\/technical-paper\/optical-encoder-grounding-and-shielding-recommendations\/","og_locale":"en_US","og_type":"article","og_title":"Optical Encoder Grounding and Shielding Recommendations","og_description":"Learn why proper shielding & grounding are essential to good servo design, & how to save time & money in the installation stage, with installation diagrams.","og_url":"https:\/\/novanta.com\/robotics-automation\/technical-paper\/optical-encoder-grounding-and-shielding-recommendations\/","og_site_name":"Robotics &amp; Automation","article_modified_time":"2026-04-07T06:45:31+00:00","og_image":[{"url":"https:\/\/novanta.com\/robotics-automation\/wp-content\/uploads\/sites\/3\/2019\/07\/Grounding-and-Shielding-Recommendations-.jpg?quality=85&strip=all&w=375&h=235&crop=1","width":375,"height":235,"type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/novanta.com\/robotics-automation\/technical-paper\/optical-encoder-grounding-and-shielding-recommendations\/","url":"https:\/\/novanta.com\/robotics-automation\/technical-paper\/optical-encoder-grounding-and-shielding-recommendations\/","name":"Optical Encoder Grounding & Shielding Recommendations | Celera Motion","isPartOf":{"@id":"https:\/\/novanta.com\/robotics-automation\/#website"},"primaryImageOfPage":{"@id":"https:\/\/novanta.com\/robotics-automation\/technical-paper\/optical-encoder-grounding-and-shielding-recommendations\/#primaryimage"},"image":{"@id":"https:\/\/novanta.com\/robotics-automation\/technical-paper\/optical-encoder-grounding-and-shielding-recommendations\/#primaryimage"},"thumbnailUrl":"https:\/\/novanta.com\/robotics-automation\/wp-content\/uploads\/sites\/3\/2019\/07\/Grounding-and-Shielding-Recommendations-.jpg?quality=85&strip=all","datePublished":"2019-05-02T16:15:04+00:00","dateModified":"2026-04-07T06:45:31+00:00","description":"Learn why proper shielding & grounding are essential to good servo design, & how to save time & money in the installation stage, with installation diagrams.","breadcrumb":{"@id":"https:\/\/novanta.com\/robotics-automation\/technical-paper\/optical-encoder-grounding-and-shielding-recommendations\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/novanta.com\/robotics-automation\/technical-paper\/optical-encoder-grounding-and-shielding-recommendations\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/novanta.com\/robotics-automation\/technical-paper\/optical-encoder-grounding-and-shielding-recommendations\/#primaryimage","url":"https:\/\/novanta.com\/robotics-automation\/wp-content\/uploads\/sites\/3\/2019\/07\/Grounding-and-Shielding-Recommendations-.jpg?quality=85&strip=all","contentUrl":"https:\/\/novanta.com\/robotics-automation\/wp-content\/uploads\/sites\/3\/2019\/07\/Grounding-and-Shielding-Recommendations-.jpg?quality=85&strip=all","width":375,"height":235,"caption":"Shielded electrical cables"},{"@type":"BreadcrumbList","@id":"https:\/\/novanta.com\/robotics-automation\/technical-paper\/optical-encoder-grounding-and-shielding-recommendations\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/novanta.com\/robotics-automation\/"},{"@type":"ListItem","position":2,"name":"Optical Encoder Grounding and Shielding Recommendations"}]},{"@type":"WebSite","@id":"https:\/\/novanta.com\/robotics-automation\/#website","url":"https:\/\/novanta.com\/robotics-automation\/","name":"Robotics & Automation","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/novanta.com\/robotics-automation\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/novanta.com\/robotics-automation\/wp-json\/wp\/v2\/novanta_tech_paper\/3266","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/novanta.com\/robotics-automation\/wp-json\/wp\/v2\/novanta_tech_paper"}],"about":[{"href":"https:\/\/novanta.com\/robotics-automation\/wp-json\/wp\/v2\/types\/novanta_tech_paper"}],"author":[{"embeddable":true,"href":"https:\/\/novanta.com\/robotics-automation\/wp-json\/wp\/v2\/users\/100"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/novanta.com\/robotics-automation\/wp-json\/wp\/v2\/media\/3260"}],"wp:attachment":[{"href":"https:\/\/novanta.com\/robotics-automation\/wp-json\/wp\/v2\/media?parent=3266"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}